Place of Origin: | China |
---|---|
Brand Name: | RECEN |
Certification: | CE, ISO9001, SGS |
Model Number: | RC-105 |
Minimum Order Quantity: | 1 |
Price: | Negotiable |
Packaging Details: | Cartons |
Delivery Time: | 5-10 days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 2000 SETS / YEAR |
Type: | Truck Scale,Control Indicator,digital Load Indicator Luggage Scale,Bench Scale,Load Cell With Indicator | Rated Load: | Under 100 Tons |
---|---|---|---|
Warranty: | 12 Months | Name: | Weight Indicator,china Weighing Indicator |
Function: | Weight Function,With Tare & Net Weight Setting | Operating Temperature: | -20~+60 ℃ |
High Light: | crane load indicator system,safe load indicator system |
Truck Crane Load Cell Indicatortensioner System Safe Load Indicator Lmi
System Profile
Signal inspection(The signal is correct in order to debug)
1.Angle sensor signal inspection,Look at the RAD in the main interface:Data,It is proportional to the size of the arm's elevation angle.;
2. Weight sensor signal check, in the main interface to view the data of WAD:, it will be proportional to the weight of the hanging.;
3.The length sensor signal is checked and the LAD: data is viewed in the main interface. It will be proportional to the elongation and retraction of the boom;
Product feature
·Do not pull cable at will, prevent breakage and break. When you need to dismantle the whole machine, you should pay attention to protecting the connecting plugs, so as not to pollute and affect the use.
·Non maintenance personnel shall not arbitrarily adjust the internal parameters of the instrument, such as abnormal, first according to the method provided in the instructions, if the failure can not be ruled out, please report to the relevant personnel.
·After the crane's working condition is changed, please change the crane working condition parameter in time, so that the crane can work normally
·This device can not prevent accidents caused by dangerous factors (not according to safety regulations). Therefore, the safety operation rules should not be neglected due to the installation of this device
·Regularly check the system accuracy (cycle 4 to 6 months) to ensure the safe use of cranes.
Working voltage: DC24V / DC12V |
Working environment temperature: - 20 C ~ + 60 C |
Relative humidity: < 95% (25 C) |
Mode of work: continuous |
Whole machine power consumption: < 20W |
Control output capacity: DC24V/1A; |
Resolution: 0.1t |
System synthesis error: <5% |
Alarm error: <3% |